Class 150 Coated Socket Steel Pipe for Water Supply
工业采购项目
准备更清晰的 RFQ
请提供以下信息,帮助 RELIA 理解零件要求并与您确认下一步。
- 图纸、样品或参考标准
- 材料牌号和首选工艺
- 尺寸、公差和表面处理
- 应用、目标数量和目的地
生产周期、包装和运输条款将在规格与贸易条件确认后按项目确定。
-
InvoicingBy Theoretical WeightOiled or Non-oiledSlightly Oiled
-
Section ShapeRoundSurface TreatmentGalvanized
-
Tolerance±10%Alloy Or NotNon-Alloy
-
ApplicationFluid Pipe, Boiler Pipe, Drill Pipe, Hydraulic Pipe, Gas Pipe, Oil Pipe, Chemical Fertilizer Pipe, Structure PipeCertificateAPI , CE, ISO 9001
-
Delivery Time31 ~ 45 daysGradecarbon steel
-
Outer Diameter150 - 350Processing ServiceWelding, Punching, Cutting, Bending, Decoiling
-
Special PipeAPI Pipe, EMT Pipe, Thick Wall PipeStandardASTM
This Class 150 coated socket steel pipe enquiry is intended for water-supply specification. The title describes inner and outer painting, while the table records Galvanized. Clarify the actual finished coating and socket arrangement before assigning performance or selecting a connection for the intended water system.
Specify the internal and external water-pipe finish
Request the proposed substrate, layer sequence and coverage on both surfaces. The source does not establish whether painting, galvanizing or a documented combination will be supplied, and no epoxy chemistry is specified. Agree preparation, thickness, cure, adhesion and inspection for the accepted coating.
Confirm coating suitability for the actual water chemistry and obtain potable-water contact approval where relevant. Define field-joint treatment, repair and protection of connection surfaces. Clarify the Slightly Oiled entry against the finished condition instead of assuming it describes every coated surface.
Complete socket geometry and the unitless wall entry
Thickness 1.2 is offered with lengths 12 m, 6 m or 6.4 m. The wall unit and the unit for outer diameter 150–350 are absent. Specify actual bore, outside diameter and wall with units, and allocate ±10% to its intended property and acceptance criteria.
Obtain socket dimensions, engagement, joint/sealing method, end preparation, assembly procedure and testing. Ask what Flexible means and request movement/load limits without assuming a flexible pipe body. Complete the steel designation, ASTM document, manufacture, condition and traceability; generic special-pipe labels are insufficient certification.
Approve Class 150 water service as an assembly
Provide pressure, temperature, cycling, water chemistry, exposure and installation loads. Confirm the applicable rating basis and joint/coating compatibility; High Pressure alone gives no numerical duty. Verify API/CE/ISO 9001 record scope, then agree support, handling, inspection, marking, documentation and quotation scope.






每个产品询价都需要的技术信息
在最终确认产品前先整理需求。
产品页只是起点。在确认库存匹配或定制生产前,我们会评审图纸、样品、接口、材料、数量及验收要求。
结合您的项目场景讨论该产品。
提供现有图纸、样品、参考件、目标数量及应用信息。尚不确定的项目可留待评审。