ERW Carbon Steel Fire Protection Pipe SCH10/SCH40
工业采购项目
准备更清晰的 RFQ
请提供以下信息,帮助 RELIA 理解零件要求并与您确认下一步。
- 图纸、样品或参考标准
- 材料牌号和首选工艺
- 尺寸、公差和表面处理
- 应用、目标数量和目的地
生产周期、包装和运输条款将在规格与贸易条件确认后按项目确定。
-
InvoicingBy Theoretical WeightOiled or Non-oiledSlightly Oiled
-
Section ShapeRoundSurface TreatmentGalvanized
-
Tolerance±1%Alloy Or NotNon-Alloy
-
ApplicationFluid Pipe, Boiler Pipe, Drill Pipe, Hydraulic Pipe, Gas Pipe, Oil Pipe, Chemical Fertilizer PipeCertificateISO 9001
-
Delivery Time31 ~ 45 daysGradecarbon steel
-
Outer Diameter150 - 350Processing ServiceWelding, Punching, Cutting, Bending, Decoiling
-
Special PipeAPI Pipe, EMT Pipe, Thick Wall PipeStandardASTM
This ERW carbon steel fire-protection pipe enquiry lists ASTM A53/A795, SCH10/SCH40 and grooved or threaded alternatives in the title. The actual variants select thickness and length only. Confirm one complete material, wall and connection specification before treating the combined references as an ordered configuration.
Select one standard, schedule and pipe-end arrangement
Request the governing A53 or A795 document and edition, full material designation, condition, traceability and certificates. Obtain ERW manufacturing evidence. The source does not establish dual certification or a particular grade, and the generic carbon steel/ASTM table entries do not complete that specification.
Allocate SCH10 or SCH40 to the selected nominal size and actual wall. Specify grooved or threaded ends separately: request groove/coupling geometry for the former, or thread standard, dimensions, engagement and joining procedure for the latter. Threaded wording alone does not identify NPT.
Resolve the unitless thickness and painted finish
Thickness 1.2 is offered with lengths 12 m, 6 m or 6.4 m. Thickness and outer diameter 150–350 lack units. Obtain the actual bore, outside diameter and wall with units, and assign ±1% to the intended dimensional property and acceptance basis.
Clarify painting in the title against Galvanized in the table. Specify the final substrate/layer arrangement, internal/external coverage, preparation, coating thickness, inspection and end protection. No epoxy chemistry or red colour is recorded. Allocate Slightly Oiled to the finished condition and agree field-joint treatment and repair.
Confirm fire-protection acceptance for the selected pipe
Provide system requirements, medium, pressure, temperature, exposure, cycling and loads, then obtain applicable approvals. High Pressure gives no numerical duty or fire listing. Verify ISO 9001 document scope and agree installation support, alignment, joint/coating testing, inspection, handling, marking, material/dimensional records and quotation scope.






每个产品询价都需要的技术信息
在最终确认产品前先整理需求。
产品页只是起点。在确认库存匹配或定制生产前,我们会评审图纸、样品、接口、材料、数量及验收要求。
结合您的项目场景讨论该产品。
提供现有图纸、样品、参考件、目标数量及应用信息。尚不确定的项目可留待评审。